Are hairline cracks in render a problem?
Fine hairline cracks are common in older sand and cement render and are usually cosmetic. They can still let water in over time, so they should be filled or the wall overcoated. Cracks that widen or run in lines through the wall need a closer look.
Hairline cracks usually come from the render shrinking as it cured, or from small seasonal movement, and they often form a fine random web known as crazing. They become a problem when rain gets in, because water held in the crack expands by about 9% when it freezes and slowly opens it further. Watch for cracks that grow over the months, run in straight lines, are wider at one end, or appear alongside sticking windows or doors, since these can point to movement in the structure. The manufacturer approach to repair is to clean the area, treat any algae, open the crack slightly so filler can key in, fill with a compatible repair material and trim it flush. Aged render is hard to colour match, so an overcoat often gives a better finish. Photographing a crack with a coin beside it for scale helps you track any change.
What causes cracks around windows in render?
Corners of windows and doors are stress points where movement concentrates. Without extra mesh patches at those corners, cracks often start there. We add diagonal mesh reinforcement at every opening corner to prevent it.
Every window and door opening breaks the wall into sections that move slightly differently, and the corners of the opening are where those movements meet. Lintels, sills and frames also expand and contract at different rates from the surrounding masonry, so stress collects there. A crack running diagonally from the corner of a window is the classic sign of render applied without reinforcement at that point. In our systems, the main glass fibre mesh runs across the whole wall, and we add an extra diagonal mesh patch at each corner of every opening, embedded in the basecoat. We also fit beads at reveals and make sure sills have proper drips, so water is thrown clear of the render below. If an existing crack keeps reopening after repair, the lintel or frame may be moving, and that should be checked before any new render goes on.
What causes horizontal cracks in render?
Horizontal cracks often follow mortar joints, steel lintels or floor lines, where materials meet or move differently. Rusting steel lintels can also expand and crack the render above windows. We check the cause before repairing.
A horizontal crack tells you something is happening along a line. A crack following a brick course often means the render is reflecting movement in a mortar joint, while one along a floor level can come from timber joists shrinking or settling. Above windows, steel lintels that have rusted expand as the rust forms and lift the render, often with brown staining showing through the crack. Cracks along the junction between old and new masonry, such as where an extension meets the house, are also common. Filling a crack without dealing with the cause means it will return. We open up suspicious cracks during the survey where we can, and if a lintel or structural issue is found, we recommend the right repair before any render goes on. Any crack that keeps widening should be looked at by a structural engineer.
Why does render crack at the corners of a house?
Corners take the most movement and knocks. Render applied without corner beads, or too thickly, cracks there first. Correctly fixed corner beads and mesh lapped round the corner prevent it.
External corners are exposed on both sides, so they dry, heat and cool faster than a flat wall, and they take knocks from ladders, bins and bikes. Render built up too thick at a corner, or finished without a bead, has little to hold it together and cracks or chips along the edge. In our systems, every external corner gets a fixed corner bead set straight and plumb, and the glass fibre mesh is lapped round the corner and onto both faces, so stress is spread across the wall. Where a corner sits next to a path or driveway, a harder wearing finish lower down can help. Corner cracks can also reflect movement in the building itself, for example where a bay or extension meets the main house, so we check whether the crack continues through the brickwork before deciding on a repair.
What is efflorescence on render?
Efflorescence is a white, powdery deposit left when water carries salts out of the wall and evaporates. It is common on new render and usually fades as the wall dries out. If it keeps coming back, there is ongoing water getting in.
Efflorescence is most common in the first months after rendering, when the wall and the fresh render are still giving up their construction water. It also appears after long wet spells, when rain soaks deeper than usual and then dries out through the face. It is not harmful in itself and can usually be brushed off with a dry stiff brush once the wall is dry. Washing it with water tends to dissolve the salts and draw them back in, so the deposit returns. If it keeps reappearing in the same place long after the render has cured, look for a persistent water source, such as a leaking gutter joint, a failed sill, or soil and planting built up against the wall. Correctly installed sills, drips and beads reduce the risk. Persistent salts should always be investigated before any redecoration.
Can render cause condensation inside?
A vapour tight render on an old solid wall can trap moisture, which may show as damp patches or mould inside. A breathable system lets the wall dry outwards. Adding external insulation also warms the wall, which reduces condensation.
Old solid brick walls, typically about 230mm thick, were built to absorb rain and let it evaporate from both faces. Seal the outside with a dense cement render or vapour tight paint, and moisture moving out from inside the house can collect in the wall instead of escaping. The wall stays cold and damp, and the inner surface becomes a likely spot for condensation and mould, especially behind furniture and in corners. A breathable render system lets vapour pass through while shedding rain, so the wall can dry outwards. External insulation goes further by keeping the masonry warm and moving the cold point outside the original wall. Inside, ventilation still matters, so extractor fans and trickle vents should be used. If you have mould on an external wall, a survey of both faces helps us see whether render, ventilation or both are involved.
Why is my render bulging?
Bulging usually means the render has lost its bond and is being pushed out by water and frost behind it, or that the wall behind is moving. It should be checked and cut out quickly, before it falls.
A bulge is render that has detached from the wall and is held up only by its own edges and any mesh within it. Water gets in through a crack above, freezes and expands by about 9%, and each winter the gap grows, so the bulge gets bigger and heavier. In some cases the wall itself is moving, for instance where a bay is settling or a wall is bowing, and the render is simply following it. Tap around the bulge and you will usually hear a hollow sound well beyond what you can see. Keep people and cars away from the area below, and have it checked promptly. We cut back to sound render, find the source of the water, repair the background and then patch or overcoat. If the brickwork behind is cracked or out of plumb, a structural check comes first.
What is render bridging the damp proof course?
It means the render runs down past the damp proof course to the ground. Moisture can then travel up the render and into the wall above, bypassing the damp proof course. We stop render above it with a bell cast bead.
The damp proof course is a waterproof layer built into the wall near its base to stop ground moisture rising. When render or paint runs over it down to the ground, it creates a route for water to bypass that barrier, either by soaking up through the render or by trapping splashback behind it. The result is often a damp tidemark inside at skirting level, peeling paint at the base of the wall outside, or render failing along its bottom edge. Raised paths and patios built up against the wall make the problem worse. We cut the render back to about 150mm above ground, fit a bell cast bead that throws water clear of the wall, and finish the plinth below so the damp proof course stays clear, usually in a dark colour that hides splashes. Check your outside ground level against the inside floor level.
Should render go down to the ground?
No. Render should stop above the damp proof course, usually 150mm above ground level, finished with a bell cast bead. Below that, the wall is left exposed or given a plinth finish that doesn't bridge the damp proof course.
Stopping the render above ground keeps it clear of rain splashback and standing water, which would otherwise soak the lower edge and lead to staining, algae and frost damage. The bell cast bead forms a neat, slightly flared drip edge, so water runs off the face and drops clear of the wall below. The strip underneath can be left as exposed brick if it is in good condition, or given a plinth finish that is breathable and does not bridge the damp proof course. We usually finish plinths in a dark colour, which hides dirt and splashes far better than a pale render. If paving or soil has built up over the years, lowering it or adding a gravel strip along the wall helps the plinth stay dry. Flower beds piled up against a wall are a common hidden cause of damp, so check yours before the survey.
Can you render a wall with rising damp?
The cause of rising damp should be fixed first. That might mean lowering ground levels, clearing blocked air bricks, or repairing the damp proof course. Rendering over an untreated damp wall traps the problem and the render will fail.
True rising damp is less common than many people assume. Damp at the base of a wall is often caused by bridging, where ground levels, paths, render or planting sit above the damp proof course, or by leaking pipes, gutters or poor drainage. Blocked air bricks can also raise moisture levels under suspended timber floors. Fixing those causes first, and letting the wall dry, often solves the problem without chemical treatment. Where the damp proof course has genuinely failed, it should be repaired or replaced by a specialist before rendering. When the wall is ready, we finish the render above the damp proof course with a bell cast bead and keep the plinth clear. On solid walls we choose a breathable system so any remaining moisture can escape. Ask any damp surveyor to explain the cause they have identified as well as the treatment they recommend.