How is external wall insulation fixed to the wall?

Insulation boards are bonded to the wall with adhesive, then secured with mechanical fixings driven through the board into the masonry. The number and type of fixings depend on the wall, the building height and how exposed it is to wind.

Before any board goes on, we check the wall is sound and reasonably flat, scraping back loose render or paint and filling hollows, because adhesive needs a solid surface to grip. On masonry the adhesive is usually applied as a continuous band round the edge of each board with dabs in the middle, so air cannot circulate behind and wind cannot get underneath. Boards are laid in a staggered bond like brickwork, with joints kept away from the corners of windows and doors, where cracks would otherwise start. Once the adhesive has set, holes are drilled through the board and the fixings tapped or screwed home, with the heads recessed and capped so they do not show through the render. On older soft brick or hollow blocks, we pull test fixings on site first to confirm they hold.

What is a starter track in external wall insulation?

A starter track is a metal or uPVC profile fixed along the base of the insulation, just above the damp proof course. It supports the first row of boards and creates a neat, drip edge at the bottom of the system.

Getting the starter track right sets the line for the whole wall, so we fix it dead level along the base, about 150mm above ground, so splashing rain and soil cannot wick moisture up into the insulation. The track is sized to the board thickness, so a 90mm board sits in a matching profile, and lengths are joined with connectors that leave a small gap for expansion. At corners the track is mitred or fitted with corner pieces so the drip line runs unbroken all the way round. On sloping ground the track steps or is cut to follow the levels, with plinth insulation used below where needed. If you have a path or patio that sits high against the wall, mention it at survey, because it affects where the track can go and may mean lowering the paving.

What is plinth insulation?

Plinth insulation is a water resistant board, usually XPS, used at the base of the wall near ground level, where ordinary insulation could get wet. It continues the insulation down the wall to reduce cold spots.

The base of a wall takes splashback from paths, puddles and soil, and ordinary EPS or mineral wool can soak up water there over time and lose much of its insulating value. XPS is a closed cell board that resists moisture, so it is used in the splash zone and, where the ground allows, a short way below path level. Stopping the insulation at the damp proof course would leave a cold band along the bottom of the ground floor, which is where condensation and mould often show up inside, along skirting boards and in the corners of rooms. The plinth board is usually finished with a tougher basecoat and a darker render colour, because this strip gets kicked, splashed and dirty. Where we dig down to fit it, we make good the path or gravel edge afterwards so water drains away from the wall.

How do you insulate window reveals?

Thinner insulation boards are fitted into the reveals around windows and doors, then rendered. Reveals are a common cold spot, and leaving them uninsulated can cause condensation inside around the frames. We include reveal insulation as standard.

Reveal boards are usually much thinner than the main wall insulation, because the gap between the frame and the edge of the opening is limited. We check this at survey, since some older frames sit so close to the outside face that there is barely room, and a slimmer, higher performance board is then used. The board is tucked up to the frame, the joint is sealed with an expanding foam tape or a frame connection bead, and corner beads with mesh give a straight, durable arris. New sills are fitted that project past the finished wall face, with end caps, so water drips clear of the render below. If you are planning new windows, it pays to fit them before the insulation and set them further forward in the opening, so the reveals can take thicker boards and the frames sit in line with the insulation.

What happens to my gas meter box with external wall insulation?

Surface mounted meter boxes are moved or extended outwards so they sit flush with the new wall face. Any work to the gas supply itself is done by your gas supplier or a Gas Safe registered engineer.

Meter boxes are one of the details that catch people out, because the supplier controls the meter and the pipe coming into it. For a surface mounted box, we either fit an extension frame so the box comes forward to the new face, or arrange for the box to be reset outward on a bracket. A recessed box built into the wall is often simpler, since the insulation can be cut neatly around it and the opening finished with a bead. We do not touch the gas supply pipe or the meter itself. Book any supplier visit early, as appointments can take some weeks, and we plan the programme around that date. Electric meter boxes are handled the same way, with the network operator responsible for anything on their side of the meter, and we leave the box door free to open.

What happens to my boiler flue with external wall insulation?

The flue usually needs extending so it still projects the correct distance from the new wall face. This must be done by a Gas Safe registered engineer, and we arrange it as part of the job.

Boiler manufacturers set how far a flue terminal must stand out from the wall, so the fumes clear the building and are not drawn back in through windows or vents. Adding insulation and render brings the wall face forward, which can leave the terminal too short. The engineer fits the manufacturer's extension piece, checks the seals and the fall back towards the boiler, and tests the appliance before signing it off. We coordinate the visit so the extension goes on after the boards and before the final render, and we leave a neat sealed collar around the flue where it passes through the system. Some older boilers have no approved extension kit, in which case the engineer may advise relocating the flue or replacing the boiler. Tell us the make and model at survey so we can check this early.

Does the roof need changing for external wall insulation?

Sometimes. If the roof overhang is small, the insulation can make the wall reach the eaves or gable verge, so the roofline may need extending to keep water off the top of the system. We check this at survey.

Insulation adds the board thickness plus render to every wall, so on a house with a small or flush eaves overhang the top of the system can end up exposed. Water running off the roof then soaks the top edge and can get behind the boards. Where there is enough projection, we finish under the soffit with a sealed trim and the roof stays as it is. Where there is not, a roofer extends the eaves by adding new rafter feet or a deeper fascia, and the gable verge is extended with new tiles or a verge trim. Gutters and downpipes are taken down and refitted on longer brackets so they sit clear of the new wall face. If you are planning roof repairs or new fascias anyway, doing both together under one scaffold saves you paying for access twice.

What are fire breaks in external wall insulation?

Fire breaks are bands of non combustible mineral wool built into an EPS system, usually at floor levels and party walls on multi storey buildings. They help stop fire spreading through the insulation. They are required on certain building types and heights.

EPS is a combustible plastic foam, so on taller or multi occupancy buildings a continuous strip of mineral wool is set into the insulation layer to interrupt any path for fire travelling upward or sideways behind the render. These strips usually run around the building at each floor level, around openings in some designs, and along the line of party walls so a fire cannot pass between homes through the insulation. Whether they are needed depends on the building type, its height and how it is used, and the system manufacturer's details set exactly where they go. On an ordinary family house, many owners choose mineral wool throughout, which removes the question and also helps with breathability and sound. Where a property is divided into flats or sits above a shop, we confirm the fire strategy with building control before pricing.

Can external wall insulation go on a semi without the neighbour doing theirs?

Yes. We finish the insulation neatly at the party wall line with a stop bead, so the step between the two houses looks deliberate. Many semis are done one side at a time.

The stop bead sits on the line of the party wall, with a sealed edge so rain cannot get behind the boards where the system ends. On the front and rear the step is the board thickness plus render, which reads as a clean change of plane once it is finished in colour. The neighbour's side stays untouched, though scaffold may need to stand on or oversail their land, so we ask their permission early and agree how their property will be protected. If they later insulate their half, their installer can butt up to our edge and the joint can be lined through. Some owners pick a colour that sits well with the neighbour's brick or render, and we can show two colour options on a photo of your house before you decide.

What thickness of render goes on external wall insulation?

Usually around 6 to 10mm in total: a basecoat with mesh of about 5 to 8mm, then a thin coat finish of about 1.5mm. Using the system's own basecoat and finish is what keeps the warranty valid.

The basecoat does most of the work. It holds the glass fibre mesh towards its outer face, which spreads stresses across board joints and helps it resist cracking and knocks. If it is too thin the mesh shows through or the coat cracks, and if it is too thick it can shrink and craze as it dries. The thin coat finish is applied at roughly the thickness of its grain, which for most finishes is 1 to 3mm, and it is floated to an even texture. On lower areas that take knocks, such as beside paths, bin stores and side passages, we often add a second layer of mesh or a heavier armour mesh in the basecoat. Mixing products from different makers can void the system warranty, which is why we keep primer, basecoat, mesh and finish within one system.